Find the symptom, then do what its row says. For an error code, see the second table.

By symptom

You seeCheckDo
The machine is offline on the pagecmdop control status.get on the machine; exit code 2 means the program is not runningStart it: cmdop run, or open the CMDOP app
status.get shows the link refusedthe machine’s key is not admitted to the contourSend the output of cmdop key to the CMDOP team
status.get shows the link failedserver in machine.jsoncmdop config set server wss://<contour>.cmdop.ai/ws/machine, then restart
The program stops at start with ceiling: …ceiling.jsonFix the JSON or the class name the message points at (ceiling.json)
The program stops at start naming machine.jsona key with a typoFix it, or cmdop config migrate for an old file
A command on a release build says the terms were not acceptedno terminal to askRun it once in a terminal, or set CMDOP_ACCEPT_AGREEMENT
An MCP client shows no CMDOP toolsthe client’s MCP settings and the tokenSet it up again from Connect an agent; a revoked token gets unauthorized
An agent sees the machine but every change is refusedthe agent’s grantA new agent has read only: grant risk classes
File tools refuse a folder the grant allowscmdop control ceiling.get → roots, and the folders no tool reachesAdd the folder to roots, then restart
Screen tools are missing or refusedscreen_info: permissions and pauseSee and control the screen: grant, ceiling, OS permissions
A task is gone after a whilewhether the machine program restartedA restart stops tasks; start it again and keep long work in tasks you can restart
A screenshot is blackscreen_info → lockedUnlock the machine; a secure input field also comes back black

By error code

CodeMeaningDo
unauthorizedthe token is wrong, revoked or of another contourUse the right token; a revoked agent is connected again as a new one
deniedthe grant or the ceiling does not allow the class, folder or appThe owner widens the grant or the ceiling; do not retry
pausedthe owner paused the machineResume at the machine (pause)
needs_presencethe change needs a person at the machineConfirm in the CMDOP app with Touch ID or the password
busy8 calls already run thereWait and retry
rate_limitedmore than 120 input actions this minuteSlow down
timed_outthe call took longer than its tool’s limitUse a task for long work
too_largearguments or result over 16 MiBRead in parts with offset, or write smaller files
hash_requiredreplacing a file without expect_sha256Get the hash with fs_stat and hash: true, then write
not_foundthe path, task or machine does not existCheck the name; machines_list and tasks_list show what exists
bad_argsthe arguments do not match the tool’s schemaFix the call against the tool’s page
permission_missingthe OS has not granted screen capture or inputTurn the named permission on in the system settings
stale_capturea pixel action without a current screenshotTake a new screen_capture first